48DCWC-16-2X100-A0 - ServerTech 48V DC PDU - PRO1 Switched -48VDC (2) 100A inputs (16) 10A outputs Rack PDU
ServerTech 48 VDC PDU (16x 10A)
Description:
The PRO1 Switched 48DCWC-16-2X100-A0 Intelligent PDU and Remote Power Manager minimizes the impact of locked-up routers, servers and other network devices on business-critical networks. CLECs, ILECs, ISPs and enterprises use the 48DCWC-16-2X100-A0 to manage equipment in remote sites, co-location facilities and network operation centers. The 48DCWC-16-2X100-A0 eliminates the need to dispatch a field service technician for manual intervention when devices lock-up. Using a 48DCWC-16-2X100-A0, the network operations center can quickly restart locked-up remote network servers to ensure that the network is fully operational around the clock.
Features:
Disconnect Rated Circuit Protection
Each output is protected by a fuse or circuit breaker and is rated for hot disconnect.
Output Current Monitoring
Network monitoring provides access to current draw at each output and alerts when high usage risks a tripped circuit.
Output Control
Cycle power to individual outputs or groups of outputs to reboot devices or to power off unused terminals.
Network Monitoring
The PRO1 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Temperature/ Humidity Monitoring
PRO1 Primary and Expansion units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
Star Multi-Linking
PRO1 provides the ability to link up to four power circuits using one IP address. First link provides backup power to network card.
Specification:
48DCWC-16-2X100-A0 (-48 VDC)
Input Power Capacity (kW): 9.6
Input Plug Type: Terminals
Input Current (A): 200
Input Current Rated (A): 200
Input Nominal Voltage (V): -48
Input Phase: DC
Input Cord Location: Horizontal
Outlet Form Factor:
Total Outlets: 16
Other Outlets: 16
Branch Monitoring:None
Branch Overcurrent Protection:
Branch Overcurrent Protection Type:Fuse Disconnect - GMT
Dual Input:Yes
High Retention Outlets:No
Input Current Display:None
Input Monitoring:None
Locking Outlets:No
Max Operating Temperature:50 °C
Mounting:2U Horizontal
Outlet Monitoring:Current (A)
PDU Platform:PRO1
Power Pivot Input:No
Product Height (inch):3.5
Product Height (mm):89
Product Max Depth (inch):13.11
Product Max Depth (mm):333
Product Nominal Depth (inch):12.0
Product Nominal Depth (mm):305
Product Width (inch):17.0
Product Width (mm):432