Partner Manufacturers - Product Information
PX3-1842V - Raritan Unit Metered iPDU: Single Phase, 230V AC, 32A, 30 Outlets: 24x IEC-C13, 6x IEC-C-19 Plug: IEC 60309 32A, 7.36 kVA, Zero U Vertical, & Sensor connections (PX-1000 Series) BTO
Raritan PX3-1842V
Description:
PX3-1842V - Raritan Unit Metered iPDU: Single Phase, 230V AC, 32A, 30 Outlets: 24x IEC-C13, 6x IEC-C-19 Plug: IEC 60309 32A, 7.36 kVA, Zero U Vertical, Ethernet, Serial, USB-A, USB-B and Sensor Connections (PX-1000 Series) BTO
The Raritan PX-1000 family of high-quality rack power distribution units (PDUs) offers real-time remote unit-level power monitoring of current (amps), voltage, power (kVA, kW), power factor and energy consumption (kWh) with ISO/IEC +/- 1% billing-grade accuracy. The PX-1000 also supports Raritan’s plug-and- lay environmental sensors. Users can define thresholds and receive alerts when thresholds are crossed for both power and environmental events.
Features:
Energy Metering
Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor
Metering Accuracy: ISO/IEC 62053-21 1%
Remote Outlet Switching:No
Metering per input line:Yes
Metering per Branch Circuit Breaker: No
Environmental Sensor Ready: Yes
Compatible Sensors: Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.
View all sensors on compatible products.
Cascading: Yes, Max 16 PDUs can be daisy chained using a USB or Ethernet connection.
Networking:Primary (10/100/1000 Base T) Ethernet with secondary redundant (10/100/1000 Base T) Ethernet in 0U, (10/100 Base T) Ethernet in 1U/2U/3U. Optional Wi-Fi (802.11ac/a/b/g/n).
Onboard Display: Color, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation
PLUG: IEC60309 32A (Single Phase)
Specification:
PX3-1842V - Raritan Unit Metered iPDU: Single Phase, 230V AC, 32A, 30 Outlets: 24x IEC-C13, 6x IEC-C-19 Plug: IEC 60309 32A, 7.36 kVA, Zero U Vertical, Ethernet, Serial, USB-A, USB-B and Sensor Connections (PX-1000 Series)
BTO - (BUILT TO ORDER)
INPUT
Input Plug IEC 60309 2P+E 6h 32A 2P3W (L1/N/E)
IP44("splashproof") (230V, Single phase)
Cord Length 3 meters (9.84 feet) standard
Cord Entry Bottom-front feed
Cable Type 2P 3W
Number of Power Cords 1
Maximum Input Current 32A (per line)
Nominal Input Voltage 230V, Single phase
Rated Input Voltage 200 - 240V, Single phase
Input Frequency 50/60Hz
Power Capacity 6.4kVA at 200V, 7.7kVA at 240V
OUTPUT
Nominal Output Voltage 230V
Rated Output Voltage 200 - 240V
Output Connections a. (24) IEC 60320 C13 2-pole, 3-wire; 10A
b. (6) IEC 60320 C19 2-pole, 3-wire; 16A
Overload Protection (2) 16A 1-pole Airpax LEGBX6-37483-16-V circuit breaker
Cable Retention Raritan SecureLockTM Ready
Optional retention clips are also available
PHYSICAL
Unit Dimensions (W x D x H) 2.1" x 2.1" x 60.6" ; 52mm x 53mm x 1539mm
Shipping Dimensions (W x D x H) 11.02" x 4.53" x 65.16" ; 280mm x 115mm x 1655mm
Color Black powder coat
Mounting RACK-KIT-PX2-1K-ZU
ENVIRONMENTAL
Operating Environment 5 - 50°C (41 - 122°F)
Operating Relative Humidity 5-85%
Operating Elevation 0-10000ft
CONFORMANCE
Regulatory Approvals CE, Canada ICES-003, Class A Part 15 Class A of the FCC rules RoHS
E&OE