PDUMH30HVAT Tripp-Lite Single-Phase Auto Transfer Switch / Metered PDU, 5/5.8kW 30A 208/240V, 2U Rackmount, 16 C13 2 C19 and 1 L6-30R outlets, two L6-30P inputs


PDUMH30HVAT

Description:
Single phase 30A 208/240V Auto Transfer Switch / ATS PDU
Enables redundant-power configurations for single-corded network devices
Separate primary & secondary inputs connect to any two compatible power sources
2U horizontal rackmount; 2 L6-30P inputs; 19 outlets (16 C13, 2 C19, 1 L6-30R)
Front panel digital display with LED indicators reports amps, kilowatts and voltage in 4 loading segments


Tripp Lite Metered ATS / Auto Transfer Switch PDU systems enable redundant power configurations for network devices with a single input cord connection. Set of two ATS inputs support connection to separate PRIMARY and SECONDARY power sources. The ATS normally maintains continuous output to connected equipment derived from the primary input. If the primary input fails or becomes unstable, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources to support a variety of advanced redundant power networking applications. Enables fault-tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time, similar to Tripp Lite SmartOnline series. ATS configurations utilizing separate mains circuits, backup generators and even out-of-phase power sources are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front panel current meter offers selectable 4 segment voltage, amperage and kilowatt loading information

Features:
208V 30A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 24A continuous)
Provides a redundant power option for critical networking equipment with a single input power cord
Digital display with selection button reports voltage, amperage and kilowatt loading information in four output segments (Segment 1: 8 C13 & 1 C19 outlets / Segment 2: 8 C13 & 1 C19 outlets / Segment 3: L6-30R outlet / Segment 4: total output of all outlets combined)
19 built-in outlets (16 C13, 2 C19, 1 L6-30R)
Set of two 10 ft. / 3m NEMA L6-30P input cables support connection to separate PRIMARY and SECONDARY power sources
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output as sourced from the secondary input cable until power on the primary input is restored and stable
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a 2 UPS environment, the primary input must be connected to an online double conversion UPS similar to Tripp Lite SmartOnline series)
Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
Super-fast switchover between primary and secondary power sources occurs in 3-6 milliseconds
Front panel LEDs confirm power availability on both input lines

Typical Applications

Ideal for datacenters, computer rooms and network closet applications to provide single-corded network hardware with redundant power in a metered PDU format

Package Includes

Auto Transfer Switch PDU
Rackmount installation brackets
Installable plug-retention shelves & cable ties

Specification:
PDU Type Metered; Auto-Transfer Switch
OUTPUT
Output Capacity Details 5kW (208V input), 5.8kW (240V input), 4.8kW (200V input); 30A maximum (agency de-rated to 24A continuous)
Frequency compatibility 60 Hz
Output nominal voltage 200-240V nominal, single phase
Outlet quantity / type 16 C13, 2 C19, 1 L6-30R
Outlet Type C13, C19, L6-30R
INPUT
PDU Input Voltage 200; 208; 240
Maximum Input Amps (A) 30
Maximum Input Amps (A) Details Agency de-rated to 24A continuous
Input connection type Two labelled NEMA L6-30P cables support Primary and Secondary input connections
PDU Plug Type NEMA L6-30P
Cable Length (m) 3
Phase Single-Phase
LEDS ALARMS & SWITCHES
Switches Set of 2 front panel switches controls amp / kilowatt / voltage selection display and primary / secondary input selection
Front panel LEDs Front panel LEDs confirms amp / kilowatt / voltage reporting information
PHYSICAL
Shipping Dimensions (HWD/in) 8 x 20.5 x 17
Shipping Dimensions (HWD/cm) 20.3 x 52.1 x 43.2
Shipping weight (lbs) 16.9
Shipping weight (kg) 7.7
Unit Dimensions (HWD/in) 3.5 (2U) x 17.5 x 12.5
Unit Dimensions (HWD/cm) 8.8 (2U) x 44.4 x 31.7
Unit weight (lbs) 16.9
Unit weight (kg) 7.7
Material of construction Steel
Style Rackmount
Form factors supported 2U rackmount
PDU Form Factor Horizontal (1U, 2U, etc)
ENVIRONMENTAL
Relative Humidity Up to 95% (non-condensing)
SPECIAL FEATURES
Appearance Black 2U rackmount steel chassis
CERTIFICATIONS
Certifications Tested to UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS Complaint
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty