Partner Manufacturers - Product Information

KWX-ATS32A2C19-H3 PDUeX Auto Transfer Switch 2 x Inputs 32A IND309 to 2 x C20 Outlets, 32 Amp Feed. High speed ATS 8~12ms. IP Switch control and Monitoring KWX-N3 Range


KWX-ATS32A2C19-H3

Description:
Auto Transfer Switch with Dual input powers provide automatically redundant power protection.
Built-in web server, manager can real time to monitoring the current consumption of the ATS.

KWX Rack mount Automatic Transfer Switch (KWX ATS). Provides Total Current Monitoring and Outlets Switching, delivers consistent power, to single-corded equipment. The KWX ATS has dual input power cords supplying power to
the connected load. In the event where the primary power source becomes unavailable, the KWX ATS will flawlessly source power from the secondary source without interrupting critical loads. The KWX ATS has built-in network
connectivity, which allows for remote management via Web, SNMP or Telnet/SSH interfaces, and provides sensors recognition, ability to cascade up to 4 units, power factor recognition, 2 x IEC60309 32A input Plug and 2 x C19 Output.
Optional: temperature and humidity, smoke alarm, water logging alarm, infrared alarm, and door open alarm.
Monitor: monitor the total current, monitor the total kWh, and monitor the input voltage, monitor environment temperature, monitor environment humidity, monitor environment smoke, monitor water logging, infrared monitoring, and
door open monitoring.
Alarm settings: total current over the limit, on the temperature limit, on the humidity limit, smoke alarm, and water logging alarm, infrared enters alarm, door open alarm. Dry connection

Features:
KWX-ATS: PDU Solution with embedded Environmental Monitoring Technology
 Monitor Temperature and humidity,
 Monitor Smoke
 Monitor Water logging
 Infrared Monitoring
 Door open Monitoring


Performance :This product has a High speed Transfer rate of between 8~12ms

Function:
- Dual input powers provide automatically redundant power protection.
- Built-in web server, manager can real time to monitoring the current consumption of the ATS.
- Built-in true RMS current meter.
- Setup easily, meter can read the IP address directly.
- Security web access by SSL.
- Provide voltage, frequency, power factor, active power, apparent power and kWh information through web interface
and SNMP.
- Provide audible alarm when the power consumption over the threshold of warning and overload.
- Send the email and traps when the power consumption exceed the trigger value of warning or overload to the PDU.
- Provide utility, it can monitor a large mount of PDU at the same time.
- Support the SNMP and provide MIB for ATS.
- Indicate input and output status with LED.
- Support to monitor temperature and humidity. (Need to purchase option accessory)

Specification:
1. Item Description
2. Product series PN-ATS-3
3. Product Size W x D x H= 19“ x 248 x 44.45 mm
4. Mounting
length
465 mm
5. Case color Black
6. Socket type
2P+E (32A) CEE form Male
Cable: 3*6.0mm2*2m
Two Inputs A&B C19 16A
7. LED display
Input/output voltage
Total load current
Power supply A or B line operating state
8. Function
Automatic switch over power A and power B
Overload alarm When over the 32A threshold both the ATS alarm and the LED display will be activated
Switching time (From "A" to "B" line): 8 ms ≤ 12 ms

Function Illustration Parameter Note
Working voltage Normal working AC90~250V
Input/output current Max input/output current 32A
16A
Working band Under normal working 47~60Hz
Access
port
Net port Via WAN or LAN monitor access 10/100Mb
Adaptive Networking
Serial port Via Serial port monitor access RS485 port
Sensor port Sensors access RS485 port
Access way
HTTP/
HTTPS Web browser access Adapt IE、Fire Fox inner core browser,
support SSL;
TELNET Simple command lines access /
SSH Encryption command lines access Support SSHV2 version
SNMP Support SNMP for centralized monitor Adapt SNMP v1、V2
Operation system compatibility Support various operation system Windows/winsta/win7/linux etc.
Secondary development
Used for system integrate Opening protocol TELNET、SSH
RS485 Customized protocol
Software upgrade Manage software load Support manage software upgrade



KWX- ATS Specification
3
Software on circuit Support software upgrade on the circuit of
hardware
Control
Control each outlets on/off Each outlet breaking capacity 16A 250VAC
Sequential power on/off
The interval of sequential power off time:
0.5s, Sequential power on 1~250s,
user-defined
Power status holding When PDU restart power, Each outlets will
remain the status before
Monitor
Monitor the input voltage
Resolution:1V
Accuracy: ±1%+1 digit
Meter range: 90~350V
Monitor the total current
Resolution: 0.1A
Accuracy: ±1%+1 digit
Meter range: 0.1~40A
Monitor the total kwh Resolution: 0.1KW·H
Accuracy: 1 grade
Monitor Environment Temperature
Resolution: 1℃
Accuracy: ±1%+1 digit
Meter range: -30~100℃
Optional
Monitor Environment Humidity
Resolution: 1%
Accuracy: ±1%+1 digit
Meter range: 01~99%
Optional
Monitor Environment Smoke Max: 25 ㎡ available Optional
Monitor water logging Water logging or drop monitor Optional
Infrared monitoring The max monitor distance: 16m Optional
Door open monitor Min. 5mm open distance available Optional
Surge protection failure monitor PDU still normal working when failure Optional
Alarm limit setting
Total current limit
Auto identify limit rationality
Temperature limit
Humidity limit
Outlets alarm
Total current over limit alarm
PS/PN series local alarm ways: PDU buzzer
alarm, sound and light alarm, Dry connect;
PN series remote alarm: E-mail, SMS,
SNMP TRAP, WEB page notice,
TELNET/SSH notice
Temperature over limit alarm Optional
Humidity over limit alarm Optional
Smoke Alarm Optional
Water logging alarm Optional
Infrared enter alarm PN series remote alarm: E-mail, SMS,
SNMP TRAP, WEB page notice,
TELNET/SSH notice
Optional
Door open alarm
Display, Indicate
Outlets indicators Each outlets with a indicator
6 digital indicators Nixie tube show the current/voltage, inquiry
products information, Alarm information;
Manu button operation
Inquiry information Inquiry product information, Alarm
information, current etc.
On/off Alarm sound, Dry connect
Close/ open alarm sound and dry connect
output, Dry connect have normal open/off
two choice, passive, touch spot can connect
2A 250VAC
Log record Alarm log Alarm log circle, Inquiry, export, stock,
delete available
Management
User right limit Administrator, Normal user
Outlets grouping Make group over PDU self sockets limit
clock synchronization Regulate PDU system clock
Intelligent recognition Outlets recognition Automatic read the sockets type and numbers
4
Sensors recognition Sensors port no need be defined, Automatic
read the sensors type and numbers
Limit recognition When over limit, setting failure
The MAX output current and PDU power Help user to limit facilities connect number
and type
Power factor recognition
Help user to know the current consuming
apparatus
Sensors in 1 ~ 8pcs same or different sensors connect in
one PDU
Flexible sensor input, extend and choose,
Customized for new sensors Optional
Cascade chain
PN with PN Cascade
Directly connection via net cable;
Via HUB ,4 sets Cascade at most
PN with PS Cascade Directly connection via net cable, 4 sets
Cascade at most