Partner Manufacturers - Product Information

PX3-1751V-F8C6 - Raritan - IP Access PDU Level Metering unit. 3Phase Wye, 380-415V AC, 32A, 30 outlets 18 x IEC C-13, 12 x IEC C-19, plug IEC 60309 32A 3P+N+PE, 21.1-23kVA, Zero U vertical PDU, Ethernet, serial, USB-A, USB-B & sensor. BTO (PX-1000 Series)


PX3 General Range PICTURE showing management module
Actual model has individual fuses, see actual ports config. line drawing. XUS716

Description:
Raritan ( PX-1000 Range ) PDU Level Metering unit. 3Phase Wye, 380-415V AC, 32A, 30 outlets 18 x IEC C-13, 12 x IEC C-19, plug IEC 60309 32A 3P+N+PE, 21.1-23kVA, Zero U vertical PDU, Ethernet, serial, USB-A, USB-B & sensor.

BTO - Special order product.

Rack Power Distribution Units for Your Data Center
Raritan’s PX3-1000 intelligent rack PDU series offers more than just power distribution -- it’s a launch
pad for real-time remote BAR level power monitoring, environmental sensors, data center infrastructure
management, and so much more.

The PX series offers hundreds of models to power all your data center applications, including
high density applications, and 400V three-phase power distribution.

Raritan offers a variety of intelligent rack power distribution models that satisfy all of your
metering requirements. Get certain off-the-shelf models delivered in as little as a few days, or
have your PDUs engineered to meet your unique application.
In the next few pages you’ll learn how Raritan was able to take over twenty-five years of
embedded computing expertise and customer insights to reinvent the rack PDU and set the gold
standard for data center power chain management. Find out why some of the world’s largest
data centers trust Raritan’s intelligent rack PDUs to power their mission critical equipment.

kWH Metering Accuracy
Accurate kWh metering allows you to measure actual energy
usage for accurate customer or department charge-back billing.
The data can be used to encourage energy efficient behavior
among users, establish power consumption baselines, and analyze
the effect of efficiency initiatives.
Soaring energy prices, greater competition in the marketplace, and global concerns over climate
change are forcing companies to reconsider how they utilize power in the most valuable and
energy intensive resource they own – the data center. It’s why data centers are now so focused on cutting operational costs by improving efficiencies, and making optimal use of energy, space, and cooling.
They’re also tasked with the most important responsibility of all: to make sure the
data, services, and pplications that we all rely on are always available. Not surprisingly, many of the major strategies being employed to address
these challenges depend on capabilities that were not present in the simple commodity power strips of a few years ago.
Consider how Raritan’s intelligent rack power
distribution units (iPDUs) help data centers to achieve those goals

Features:
Energy Metering Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power
Factor

Metering Accuracy ISO/IEC 62053-21 1%
Metering per Input Line Yes
Metering per Branch Circuit Breaker Yes
Metering per Output Receptacle No
Remote Outlet Switching No
Environmental Sensor Ready Yes
Networking 10/100 BaseT Ethernet. Optional WiFi (802.11a/b/g/n)
Remote Management HTTP(s); SSH; Telnet; RS-232 (Serial); Power IQ; SNMP version v2/v3; SMTP; JSON-RPC

Cascading Yes - Max 8 PDUs can be daisy chained using a single Ethernet connection
Onboard Display User-selectable display (voltage, current, or active power:per line, per breaker, or per
receptacle)
Compatible Sensors
Temperature, Humidity, Air Flow, Static Pressure
Single cable connection provides temp/humidity monitoring
at three points in cabinet (with a single sensor assembly)
Replaceable controller

Power Metering and Monitoring

Remote power monitoring, metering and rich data collection including current (amps), voltage, power (kVA, kW) and energy consumption (kWh) Make informed capacity planning decisions and efficiently utilise power resources such as finding stranded power in racks. Measure IT equipment power consumption to save power and money, calculate Green Grid’s PUE Level 2 and Level 3, and drive green data centre initiatives.

LED and alarms for unbalanced loads based on user-adjustable thresholds Increase efficiency, utilization and capacity. Load balance lines and circuits to avoid overloading neutral lines. Improve uptime and staff productivity.

Capable of ISO/IEC +/- 1% billing-grade accuracy real-time power monitoring and metering, down to individual outlets for some models Report and/or bill back power consumption (kWh). Trend and track energy utilization or bill power costs to users.

User-adjustable power data sampling and buffering End users can choose the frequency at which they monitor power and the amount of data they gather.

Power Management, Security and Remote Access

Alerts via SNMP, e-mail and syslog from individual outlets, units, lines and circuit breakers when user-adjustable thresholds are exceeded Receive advanced warning of potential problems with critical and non-critical thresholds and alerts.

Standards based polling, configuration and alerting with encryption via SNMP v1, v2, v3 support, SETs, GETs and TRAPs Increase uptime with alerts. Collect data for trending and capacity management.

Ethernet, serial, USB-A, USB-B and sensor connections Supports modem control functions for serial console access. Connectivity options for third-party peripherals enabling new applications, e.g., wireless, USB drives, etc.

Directory services support providing advanced authorization options, including permissions, LDAP/S, RADIUS and Active Directory®. 256-bit AES encryption and strong passwords Configure user access rights and security settings.

Remote access via Web and CLI. Supports HTTP, HTTPS, SSH and Telnet Check status of PDUs, lines, circuit breakers and individual outlets. For switched models, remotely provision (turn on), reboot and switch individual outlets and groups of outlets with user-configurable, outlet-level delays for power sequencing.

Compatible with Raritan’s Power IQ® Centralize power control and analytics and measure CO2 footprints.

Environmental Monitoring

Environment-monitoring-ready intelligent rack PDUs with optional plug-and-play environmental sensors

Monitor temperature and humidity to identify hot spots, confidently raise the ambient temperature of your data center to reduce cooling power consumption and manage static problems. Increase efficiency with ASHRAE guidelines.

Alerts based on user-defined environmental thresholds Save costs by leveraging PX to monitor the data center environment and receive alerts when thresholds are reached.

LED indication if sensor is plugged in and detected Provides confidence that environmental sensors are functioning and properly monitoring the data center environment.

Hardware

Hundreds of models Meets all your data center applications, including models with outlet switching and individual outlet metering.

High-power, including 400V power distribution and high temp 60C models For high-heat environments such as blade servers, high-density applications and storage area networks (SANs). Supports hot aisle containment and high-power blade racks.

High-quality construction and components such as solder connections to copper bus bars in PCBs, ISO 9000 quality manufacturing and quality components from Tyco, Hubbell® and Mennekes® Superior reliability compared to other rack PDUs available.

Lightweight and strong extruded aluminum chassis with excellent heat dissipation and versatile button and bracket mounts Mounting flexibility.

Designed with 3D CAD/CAM software Up to 36% less deep than competitive products for easier rack mounting and minimal equipment and airflow blocking.

UL489 circuit breakers Meets Underwriters Laboratories’ latest branch circuit protection standards. Unlike fuses, an electrician or an inventory of spare fuses are not required. Eliminates the possibility of installing a fuse with the wrong rating.

Smart reversible LED display that changes orientation Easily check power readings, such as line draw and balance for three-phase rack PDUs at the rack before adding devices. Increases installation flexibility.

Raritan’s 25 years of data centre management and embedded development experience led to the embedded high-performance processor Rich and full implementation network management, directory services and security with best-in-class user experience.

Scalability and headroom for future upgrades.

Specification:
INPUT
Input Plug IEC 60309 3P+N+E 6h 32A 4P5W (L1/L2/L3/N/E)
IP44("splashproof") (400V, 3 phase)
Cord Length 3 meters (9.84 feet) standard
Cord Entry Bottom-bottom feed
Cable Type 4P 5W
Number of Power Cords 1
Maximum Input Current 32A (per line)
Nominal Input Voltage 400V, 3 phase
Rated Input Voltage 380 - 415V, 3 phase
Input Frequency 50/60Hz
Power Capacity 21.1kVA at 380V, 23.0kVA at 415V

OUTPUT
Nominal Output Voltage 230V
Rated Output Voltage 220 - 240V
Output Connections a. (18) IEC 60320 C13 2-pole, 3-wire; 10A
b. (12) IEC 60320 C19 2-pole, 3-wire; 16A
Overload Protection a. (18) 20A 1-pole RFMB-10 circuit breaker
b. (12) 20A 1-pole RFMB-16 circuit breaker
Cable Retention Raritan SecureLockTM Ready
Optional retention clips are also available

Unit Dimensions (W x D x H) 2.8" x 2.4" x 67.7" ; 70mm x 60mm x 1720mm
Shipping Dimensions (W x D x H) 14.37" x 5.31" x 83.07" ; 365mm x 135mm x 2110mm
Color Black powder coat
Mounting Tool-less button mount

Operating Environment 5 - 60°C (41 - 140°F)
Operating Relative Humidity 5-85%
Operating Elevation 0-10000ft

Regulatory Approvals
CE
Canada ICES-003, Class A
Part 15 Class A of the FCC rules
RoHS compliant